Zijuan Tang
A U-Shape Fibre-Optic pH Sensor Based on Hydrogen Bonding of Ethyl Cellulose with a Sol-Gel Matrix
Tang, Zijuan; Gomez, David; He, Chenyang; Korposh, Serhiy; Morgan, Stephen P.; Correia, Ricardo; Hayes-Gill, Barrie; Setchfield, Kerry; Liu, Liangliang
Authors
Dr DAVID GOMEZ DAVID.GOMEZ@NOTTINGHAM.AC.UK
Assistant Professor
Chenyang He
Professor SERHIY KORPOSH S.Korposh@nottingham.ac.uk
PROFESSOR OF PHOTONICS INSTRUMENTATION
Professor STEVE MORGAN STEVE.MORGAN@NOTTINGHAM.AC.UK
PROFESSOR OF BIOMEDICAL ENGINEERING
Dr RICARDO GONCALVES CORREIA RICARDO.GONCALVESCORREIA@NOTTINGHAM.AC.UK
ASSISTANT PROFESSOR IN OPTICAL FIBRE SENSING
Professor BARRIE HAYES-GILL BARRIE.HAYES-GILL@NOTTINGHAM.AC.UK
PROFESSOR OF ELECTRONIC SYSTEMS AND MEDICAL DEVICES
Kerry Setchfield
Liangliang Liu
Abstract
© 1983-2012 IEEE. Development of a biocompatible pH sensor is of importance in biomedical applications, particularly for in vivo measurement, providing necessary information for clinical diagnosis and treatment such as chronic wounds and foetal acidosis. Traditional pH-indicator based optical sensors have problems of dye-leaching and photobleaching that restrict their uses in long-term monitoring. In this work, a dye-free fibre optic pH sensor is proposed consisting of a U-shape multimode optical fibre coated with a hybrid organic-inorganic composite film. The film is formed by cross-linking ethyl cellulose with a silica matrix at an optimised ethyl cellulose/silica molar ratio of 0.0065 via weakly interacted hydrogen bonding. This bonding is affected by hydrogen concentration (i.e., pH) in a solution resulting in a morphological change of the polymer aggregation presented in the silica matrix leading to refractive index change of the film. The developed sensor shows a reversible response to pH from 4.5 to 12.5 and exhibits linear correlation between transmitted light power and pH with a limit of agreement (LoA) between the sensor and a commercial probe of ±0.2 pH. For a clinically important range of pH values between 6 and 8 the LoA is ±0.1 pH. The sensor has low cross-sensitivity to temperature as the maximum interpreted pH change attributed to the power change is 0.12 pH when the temperature changes from 21 °C to 39 °C. To demonstrate biomedical relevance, the sensor is used to monitor pH of human serum. An in-house cytotoxicity assay is conducted with mouse fibroblast cell revealing that the film is not cytotoxic.
Citation
Tang, Z., Gomez, D., He, C., Korposh, S., Morgan, S. P., Correia, R., Hayes-Gill, B., Setchfield, K., & Liu, L. (2021). A U-Shape Fibre-Optic pH Sensor Based on Hydrogen Bonding of Ethyl Cellulose with a Sol-Gel Matrix. Journal of Lightwave Technology, 39(5), 1557-1564. https://doi.org/10.1109/JLT.2020.3034563
Journal Article Type | Article |
---|---|
Acceptance Date | Oct 26, 2020 |
Online Publication Date | Oct 28, 2020 |
Publication Date | Mar 1, 2021 |
Deposit Date | Nov 12, 2020 |
Publicly Available Date | Nov 12, 2020 |
Journal | Journal of Lightwave Technology |
Print ISSN | 0733-8724 |
Electronic ISSN | 1558-2213 |
Publisher | Institute of Electrical and Electronics Engineers |
Peer Reviewed | Peer Reviewed |
Volume | 39 |
Issue | 5 |
Pages | 1557-1564 |
DOI | https://doi.org/10.1109/JLT.2020.3034563 |
Keywords | Atomic and Molecular Physics, and Optics |
Public URL | https://nottingham-repository.worktribe.com/output/5035829 |
Publisher URL | https://ieeexplore.ieee.org/document/9242239 |
Files
U-shape fibre-optic pH sensor
(1.9 Mb)
PDF
Publisher Licence URL
https://creativecommons.org/licenses/by/4.0/
U-shape fibre-optic pH sensor
(393 Kb)
PDF
You might also like
Localised plasmonic hybridisation mode optical fibre sensing of relative humidity
(2021)
Journal Article
Polymeric fibre optic sensor based on a SiO2 nanoparticle film for humidity sensing on wounds
(2016)
Presentation / Conference Contribution
Comparing peripheral limb and forehead vital sign monitoring in newborn infants at birth
(2024)
Journal Article
Downloadable Citations
About Repository@Nottingham
Administrator e-mail: discovery-access-systems@nottingham.ac.uk
This application uses the following open-source libraries:
SheetJS Community Edition
Apache License Version 2.0 (http://www.apache.org/licenses/)
PDF.js
Apache License Version 2.0 (http://www.apache.org/licenses/)
Font Awesome
SIL OFL 1.1 (http://scripts.sil.org/OFL)
MIT License (http://opensource.org/licenses/mit-license.html)
CC BY 3.0 ( http://creativecommons.org/licenses/by/3.0/)
Powered by Worktribe © 2024
Advanced Search